Skip to main content Skip to search Skip to main navigation
All FAQ Topics LEDAQUARISTIK HELP CENTER

Frequently Asked Questions (FAQ)

Find helpful answers and practical guidance on your selected topic.

Questions & Answers

Click on a question to view the corresponding answer.

What are the differences between the various control systems?

Which Lighting Controller Is Right for You?

Compare the features and technical specifications of our lighting controllers. Select the models you want to compare and choose to display only the differences. On smartphones, you can compare two controllers side by side.

¹ Depending on firmware version and configuration. ² Limited functionality on SimuLUX 24. ³ Programming via separate Windows software.

An automatic lighting controller with daylight simulation offers numerous benefits – both for your aquarium inhabitants and for you. Instead of switching the lighting on and off abruptly, it creates natural lighting cycles with smooth transitions between day and night.

Natural Lighting Conditions and Less Stress

Sudden changes in lighting can startle fish and cause unnecessary stress. With automatic daylight simulation, the day begins with a gentle sunrise, the brightness gradually increases and slowly decreases again towards the evening.

These smooth transitions reflect the animals' natural daily rhythm and can help encourage calmer behaviour. At the same time, you can enjoy beautifully atmospheric lighting without your aquarium suddenly going dark in the evening.

Customised Lighting Cycles and Impressive Effects

Depending on the model, our lighting controllers offer 2 to 10 independently programmable channels. This allows you to control different LED bars or light colours separately, adjusting their brightness and timing to create individual lighting schedules.

Depending on the controller model, the following features are available:

  • Sunrise and sunset: Smooth transitions between warm morning light, bright daylight and evening twilight.
  • Moonlight: Subtle nighttime illumination with individually adjustable brightness.
  • Weather effects: Simulation of cloudy conditions, rainy days and – on suitably equipped models – dynamic thunderstorms with lightning effects.
  • Customised daily schedules: Different lighting phases, brightness transitions and, depending on the model, separate programmes for individual days of the week.

Save Energy with Intelligent Dimming

Another important benefit is the potential for energy savings. With daylight simulation, not all LED bars need to operate at full power throughout the day. Adjusting their brightness according to your lighting schedule can help reduce electricity consumption.

Even a moderate reduction in brightness can save energy without making the lighting appear noticeably dimmer. Lower operating temperatures may also have a positive effect on the service life of the LEDs.

Our conclusion: Automatic lighting control combines natural lighting conditions, flexible customisation and energy-efficient operation. Your aquarium inhabitants benefit from gentle lighting transitions, while you enjoy a beautifully illuminated aquarium with varied lighting effects every day – completely automatically.

Compare Our Lighting Controllers »

Are Your LED Lights Dimmable?

Yes, all our eco+, PRO² and aquaLUMix LED bars, as well as spotBEAM and powerBEAM lights, are dimmable. A compatible dimmer allows you to adjust the brightness individually. With one of our automatic lighting controllers, you can also programme timed lighting sequences.

Depending on the lighting system, several independently dimmable channels are available. This allows you to adjust not only the brightness but also individual light colours and their combinations.

Can I Simulate a Natural Daylight Cycle?

Yes, our lighting controllers allow you to create a complete daylight cycle with gradual sunrise, daylight, sunset and moonlight. Depending on the controller, additional effects such as passing clouds, thunderstorms and other lighting scenarios are also possible.

  • eco+: Different light colours can be combined and controlled individually. Additional effect colours such as RED for sunrise and ROYAL BLUE for moonlight allow particularly varied daylight simulations.
  • PRO²: Depending on the version, two light colours within a single LED bar can be controlled independently – ideal for smooth colour transitions.
  • aquaLUMix: Preconfigured, coordinated light colours with four independently controllable channels provide a wide range of daylight and effect lighting options.
  • spotBEAM: Three independently dimmable channels allow customised lighting moods and natural daylight cycles.
  • powerBEAM: Depending on the version, two or three dimmable channels are available, allowing daylight simulations and moonlight effects even in large aquariums.

Good to know: A compatible lighting controller is required for automatic daylight simulation. Control options and dimming ranges vary depending on the product. For example, the powerBEAM main light can be dimmed from approximately 10–100%, while the separately powered effect channels can be adjusted from 0–100%.

Our recommendation: A programmable daylight simulation not only creates natural lighting transitions but also allows you to adjust the light output to your actual needs, helping to reduce energy consumption.

Yes, many dimmable LED lights from other manufacturers can be operated with our SunRiser lighting controllers. The lighting system must be electrically compatible and designed for a DC operating voltage between 12 and 24 V. This allows existing aquarium lighting to be upgraded with individual daylight simulations.

What Should Be Considered When Connecting Third-Party LED Lights?

Our SunRiser controllers feature removable screw-terminal connectors. The lighting and power supply can be connected directly using these terminals. We also offer suitable connection adapters for various third-party lighting systems, allowing existing connectors to be retained in certain cases.

  • Operating voltage: SunRiser 6 and 10 support 12–24 V DC. The lighting must be compatible with the selected supply voltage.
  • No mixed voltages: Lights requiring different voltages, such as 12 V and 24 V, must not be operated together on the same controller.
  • Power supply: A suitable constant-voltage power supply is required, with sufficient capacity for all connected lights.
  • Dimming compatibility: The lighting must support the PWM dimming method used by the controller. Matching voltage alone does not guarantee compatibility.
  • Power limits: Neither the maximum current per channel nor the controller's total current rating may be exceeded.
  • Polarity: Positive and negative wires must be connected correctly. Wire colours can vary between manufacturers and product generations.

For SunRiser 6 and 10, the maximum current is 5 A per channel and 20 A in total. This corresponds to a maximum of 60 W per channel and 240 W total at 12 V, or 120 W per channel and 480 W total at 24 V.

Important: Connection adapters do not convert voltage. They only adapt the physical connector. Lighting systems with integrated electronics, proprietary control protocols or constant-current drivers require additional compatibility checks.

Multicolour Lighting with a Common Positive Wire

Many multicolour LED fixtures use a shared positive (+) connection and separate negative (−) wires for each light colour. To control these colours independently, the common positive connection must be distributed to the required SunRiser channels using suitable connection terminals.

The following image illustrates this wiring principle using an older SunRiser controller. The same basic principle can also be applied to suitable current models.

Example showing a shared positive wire distributed across multiple SunRiser channels

Compatibility Overview for Third-Party Lighting

The following table shows previous compatibility experience with various lighting systems. The specifications refer to the documented older versions and should not automatically be applied to newer generations.

Manufacturer / Model Operating Voltage Compatible with 12 V Power Supply? SunRiser Compatible? Adapter
Aquatlantis Easy LED 24 V No Yes* Available
Daytime eco / Cluster 12 V Yes* Yes* Available
Daytime onex 24 V No Yes* Direct wiring documented
Econlux SolarStinger SunStrip 24 V No Yes* Direct wiring documented
EHEIM classicLED 24 V No Yes* Direct wiring documented
EHEIM PowerLED 12 V Yes* Yes* Available
EHEIM PowerLED+ 24 V No Yes* Available
JUWEL HeliaLux LED Depends on model No Selected models* Direct wiring documented
JUWEL NovoLux LED 24 V No Yes* Available
Sera X-Change 20 V No Yes* Available

*Compatibility depends on the specific product generation, electrical design, dimming capability and a suitable power supply. Please verify the specifications and adapter availability for your exact model before making any connections.

Examples of Multichannel Connections

Econlux SolarStinger Fresh 35 / older SunStrip versions: The documented RGBW version allows the white, red, green and blue channels to be controlled independently. An additional sixth wire may serve a different function depending on the model.

  • Brown: common positive (+)
  • White: negative (−), white channel
  • Red: negative (−), red channel
  • Green: negative (−), green channel
  • Blue: negative (−), blue channel
  • Yellow: unused on the tested model; may serve an additional colour channel on other versions

Example of an older Econlux SolarStinger RGBW fixture connected to a SunRiser controller

JUWEL HeliaLux LED, older two-channel version: The documented model allows separate control of white and blue light.

  • Brown: common positive (+)
  • Grey: negative (−), white channel
  • Blue: negative (−), blue channel

Example of an older JUWEL HeliaLux LED connected to a SunRiser 2

Daytime onex, documented version:

  • Grey: positive (+)
  • White: negative (−)

EHEIM PowerLED+: Depending on the version, several light channels may be controlled separately. As different wire assignments have been documented, the wiring must be verified for the specific model before connection.

Example of an older EHEIM PowerLED+ connected to a SunRiser 8

Warning: The connection examples shown above originate from previous product tests. Wire colours are not universally standardised across the listed manufacturers. Never connect a light based solely on the illustrated wire colours. Always check the voltage, polarity, channel assignment and any manufacturer-specific requirements first.

All wiring must be carried out only on the designated low-voltage connections with the power supply disconnected. Modifications to the 230 V mains side are not permitted. If you are unsure, we will be happy to help you check the compatibility of your existing lighting.

Our recommendation: When contacting us, please provide the exact model name of your LED fixture together with a photograph of its rating label and connector. This will help us identify a suitable controller, power supply and any necessary adapters more reliably.

A light control can only ever control the brightness of the LEDs. The light colour of the individual LED bar or the respective channel of the lamp is fixed. Depending on the mixing of the individual LED bars/channels by the control unit, a different overall colour results.

Example:

LED SUNRISE 100% and LED AFRICAN-SUN 10% = a warm light

LED SUNRISE 50% and LED AFRICAN-SUN 50% = a neutral light